Youngbo Australia
15/853 Nudgee Rd
Northgate Qld 4013
(07) 3267 7100
(07) 3267 7166
youngbo.com.au
|

CLOSED CELL |
- |
Will not absorb water should condensation occur. |
| |
|
|
FACTORY BONDED FOIL |
- |
Foil is thermally bonded, it will not delaminate with time as can potentially happen with glued foils |
| |
|
|
TOUGH AND FLEXIBLE |
- |
Thermobreak™ Tube SPI is tough, durable, but flexible which allows quick installation in tight and restricted places |
| |
|
|
GOOD COMPRESSION RESISTANCE |
- |
Tough, robust , yet flexible foam. Thermobreak™ Tube will not compress
during the life of the installation |
| |
|
|
IMPERMEABLE TO
WATER
VAPOUR |
- |
Thermobreak™ Tube SPI has a low level of water vapour transmission due to the tight molecular structure of the foil and the nature of the closed cell foam. |
| |
|
|
OUTDOOR USE |
- |
The UV resistant foil used in Thermobreak™ Tube SPI allows the product to be used in outdoor applications. |
| |
|
|
NON FIBROUS |
- |
Thermobreak™ Tube SPI does not emit dust or fibres, and will not cause itchiness, so no special gloves or masks are required. |

Thermobreak™ TUBE SPI CUTS INSTALLATION TIME BY A THIRD!!!
Here's why:
- The tough, 2 meter flexible foam allows for installation in restricted areas and the 2 meter length
reduces the number of joins.
- Each section is pre-slit, just open and slip over the pipe. The foam will close easily to allow quick
and easy application of the foil tape.
- The robust nature of the foam and foil makes “mitrering” easy. A sharp long blade knife is all that
is needed. The tube will not collapse when cut, ensuring a neat accurate cut.
- The flexibility of the tube allows compression but ensures it will return to it original size.
Tip: Cut the foam tube 15– 20 mm longer than the distance between blocks, slip the foam
over the pipe, compress and let it expand onto the blocs. This will ensure a tight seal
between blocks and insulation. No more “shaving of the insulation to fit the gap.
- Building Site “house keeping” is reduced due to the clean, no mess nature of the product, once
again contributing to reduced labour and associated costs.
COMPLYING WITH THE BCA & AUSTRALIAN STANDARDS
- BCA 2006 & AS/NZS 4859.1 specified R values for insulation of pipes
- AS/NZS 3500.4, which states all insulation exposed to the weather should be "of a weather
resistant type or surrounded by a weather resistant covering".
- AS1530.3 with the following results:
| |
Ignitability Index
Spread of Flame Index
Heat Evolved Index
Smoke Evolved Index |
0
0
0
1 |
(0 - 20)
(0 - 10)
(0 - 10)
(0 - 10) |
TECHNICAL DATA
| |
Material |
Crosslinked closed cell polyethylene foam |
| |
Density |
25kg/m3 |
| |
Operating temperature range |
-40°C to 105°C |
| |
Thermal conductivity |
0.038 W/m.K @ 23°C (ASTM C177) |
| |
Water vapour transmission |
0.05g/hr.m2 (9.54 x 10-8g/Pa.m2.s) (ASTM E96) |
| |
Resistance to Mould |
Excellent |
| |
Resistance to Ozone |
Excellent |

- Wall thickness: From 10mm up to 50mm
- Internal Diameters (ID): All common sizes are available for Copper, Steel and Plastic
- Thermobreak™ Tube is available in rolls, with and without adhesive backing
The figures contained in this brochure are not standard but merely representative values from tests KSM3014.Youngbo Australia makes no warranty
or recommendations as to the use of Thermobreak™ Tube SPI for a particular purpose. Further, data contained herein are typical laboratory
results only, and do not represent a guarantee of performance in any application. It is the customer’s responsibility to satisfy himself that the product
is fit for the purpose for which he intends to use it
|